Legend Coupe V6-2675cc 2.7L SOHC FI (1988)
Air Door Actuator / Motor: Testing and Inspection
Component Test
1. Connect the battery positive to the 3 terminal of the recirculation control motor connector and negative to 1 terminal.
2. Using a jumper wire connect the 1 terminal and 2 or 4 terminal.
-
On the recirculation door REC position, the motor should turn with the 1 terminal connected to 2 terminal.
-
On the door FRESH position, the motor should turn with the 1 terminal connected to 4 terminal.
4. The motor automatically stops after half turn with the jumper wire connected.