acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Diagnostic Flowchart > < Diagnostic Flowchart|Coupe|Page 5224
Page 1
background image

Air Door Actuator / Motor: Testing and Inspection
Component Test

1. Connect the battery positive to the 3 terminal of the recirculation control motor connector and negative to 1 terminal.
2. Using a jumper wire connect the 1 terminal and 2 or 4 terminal.

-

On the recirculation door REC position, the motor should turn with the 1 terminal connected to 2 terminal.

-

On the door FRESH position, the motor should turn with the 1 terminal connected to 4 terminal.

4. The motor automatically stops after half turn with the jumper wire connected.

Diagnostic Flowchart > < Diagnostic Flowchart|Coupe|Page 5224