Legend Coupe V6-3206cc 3.2L SOHC FI (1991)
Air Door Actuator / Motor: Specifications
Automatic Climate Control
Mode Control Motor
RESISTANCE SPECIFICATIONS
Between No. 3 and 5 terminals ................................................................................................................................................................. approx. 6 K Ohms
Between No. 4 and No. 5 terminals [1]
In VENT Position ........................................................................................................................................................................ approx. 1.2 K Ohms
In DEF Position ........................................................................................................................................................................... approx. 4.8 K Ohms
[1]
Tested while briefly applying power to No. 2 terminal and grounding No. 1 terminal. Also tested in same manner with polarity reversed.