acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Receiver Dryer > < Blower Motor - Always Runs On HIGH|Page 8774
Page 1
background image

Power Transistor HVAC: Testing and Inspection
Component Test - Manual Heating and Air Conditioning

NOTE: The power transistor cannot be tested with ordinary circuit testers. If the blower motor does not operate and you feel that the problem may be the
power transistor, test it as described below.

1. Check the blower motor and its wire harness.

-

If they are not OK, repair or replace them as necessary, then retest.

-

If they are OK, go to step 2.

2. Disconnect the wire harness from the power transistor. Pull out the LT GRN/BLK lead from the connector and connect a 1.2 - 3.4 watt bulb as

shown. Then, reconnect the wire harness to the transistor.

CAUTION:
-

To avoid a loose or disconnected terminal, be careful not to damage the locking tab when disconnecting and connecting the terminal.

-

Insulate the LT GRN/BLK lead terminal from the body until the testing is completed.

3. Turn the ignition on.

-

If the blower motor now operates, the controller is faulty. Replace it and retest.

-

If the blower motor still does not operate, the power transistor is faulty. Replace it and retest.