2. Measure the resistance between the No.7 and No.8 terminals of the transmission sub-harness.

STANDARD:  5.0-5.6 ohms (at 7O°F, 20°C) or 4.8-5.4 ohms (at 70°F 20°C)

3. If the resistance is Out of specification, disconnect the transmission sub-harness from the shift control solenoid valve/linear solenoid harness

connector.

4. Measure the resistance between the C and D terminals of the shift control solenoid valve/linear solenoid harness connector.

STANDARD:  5.0-5.6 ohms (at 70°F, 20°C) or 4.8-5.4 ohms (at 70°F, 20°C)

5. Replace the transmission sub-harness if the resistance is within specification.
6. Replace the linear solenoid if the resistance is out of specification.
7. Connect the C terminal of the shift control solenoid valve/linear solenoid harness connector to the battery positive terminal and connect the D

terminal to the battery negative terminal. A clicking sound should be heard.

8. If not, replace the linear solenoid.