acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Starting System > < Voltage Regulator|Specifications|Page 7499
Page 3
background image

Fig. 5 Full Field

8.

Ensure cooling fans are off, accelerate and hold engine at 2000 RPM, then apply a load with carbon pile so that voltage drops to no less than 12
volts. Check maximum amperage reading and compare to specifications, Figs. 8 and 9. Subtract 5 to 10 amps from reading to allow for engine
operation.

9.

If reading obtained in previous step is within specified range, charging system is operating normally. If not, proceed to next step.

10.

Attach probe to full field test lead on analyzer and insert probe into access hole at back of alternator, Fig. 5. Switch analyzer to ``A'' (ground)
position and check maximum amperage reading. Voltage will rise quickly when performing this operation. Do not allow voltage to exceed 18
volts, or damage to system may result.

11.

If reading obtained in previous step is not within specified range, replace alternator. If reading obtained is as specified, replace voltage regulator.