acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Mechanical Specifications|Page 1606 > < Oil Filter, Engine|Locations|Page 1600
Page 1
background image

Hose/Line HVAC: Mechanical Specifications

APPLICATION

LINE, HOSE OR BOLT DIAMETER ....................................................................................................................................................  TORQUE

Discharge Hose (Condenser Side) 

3/4 in (12.7 mm) ................................................................................................................................................................................  22 Nm (16 lb-ft)

Discharge Hose (Compressor Side) 

8 mm bolt ...........................................................................................................................................................................................  30 Nm (22 lb-ft)

Suction Hose (Evaporator Side) 

7/8 in (14.5 mm) .............................................................................................................................................................................  32.5 Nm (23 lb-ft)

Suction Hose (Compressor Side) 

8 mm bolt ...........................................................................................................................................................................................  30 Nm (22 lb-ft)

Condenser Pipe 

3/4 in (12.7 mm) ................................................................................................................................................................................  22 Nm (16 lb-ft)

Receiver Pipe 

9/16 in (8.0 mm) .............................................................................................................................................................................  13.5 Nm (10 lb-ft)

Mechanical Specifications|Page 1606 > < Oil Filter, Engine|Locations|Page 1600