Positive Crankcase Ventilation: Testing and Inspection
Coupe

Inspection 

1. Check the crankcase ventilation hoses and connections for leaks and clogging.
2. Remove the breather chamber cover and connect a vacuum pump to the PCV valve.

3. Pinch the hose as illustrated, apply 400 - 500 mmHg (16 - 20 in.Hg) of vacuum then unpinch the hose and quickly check for a clicking sound on

the PCV valve.
-

If no clicking sound is heard, replace PCV valve and recheck.