Condenser Fan Motor Relay: Testing and Inspection

Relay Test

NOTE: All A/C system relays are similar.

1. Check for continuity between terminals (3) and (4). There should be no continuity.

2. Connect a 12V battery across terminals (1) and (2). There should be continuity between terminals (3) and (4).