acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Voltage Regulator|Specifications|Page 4943 > < Voltage Regulator|Specifications
Page 1
background image

Voltage Regulator: Testing and Inspection

1986-87

1.

Ensure battery is fully charged and that alternator belt, connections at alternator and main fuses are in satisfactory condition.

2.

On Integra models, ensure fuse No. 4 in the dash fuse panel is in satisfactory condition.

3.

On Legend models, ensure fuse No. 11 in the dash fuse panel and No. 36 in the underhood relay box are in satisfactory condition.

4.

On all models, disconnect electrical connector from alternator.

5.

Turn ignition switch on and ensure battery voltage exists between alternator connector black/yellow wire terminal and ground and, on Legend
models, between yellow/blue wire terminal and ground.

Fig. 1 Alternator test connections. 1986-87

6.

If voltage is indicated as described in step 5, connect a voltmeter and ammeter to alternator as shown, Fig. 1.

7.

Start engine, turn on headlamps and rear defroster and set blower fan on high speed.

Voltage Regulator|Specifications|Page 4943 > < Voltage Regulator|Specifications