acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Blower Motor > < System View|Page 7378
Page 1
background image

Aspirator Fan: Service and Repair

CAUTION:

-

All SRS wiring harnesses are covered with yellow outer insulation.

-

Before disconnecting any part of the SRS wire harness, install the short connectors.

-

Replace the entire affected SRS harness assembly if it has an open circuit or damaged wiring.

1. Remove the climate control unit.

NOTE: The L and LS model radios may have a coded theft protection circuit. Be sure to get the customer's code number before:
-

Disconnecting the battery.

-

Removing the No. 56 (7.5A) fuse in the under- hood fuse/relay box.

-

Removing the radio.

After service reconnect power to the radio and turn it on. When the word "CODE" is displayed, enter the customer's 5-digit code to restore radio
operation.

2. Disconnect the aspirator fan connector as shown.
3. Remove the mounting screws, then remove the aspirator fan motor.