Ambient Temperature Sensor / Switch HVAC: Testing and Inspection
Component Test

Compare the resistance reading between terminals of the outside air temperature sensor with specifications shown in the graph: It should be within
specifications.

Resistance at 68°F (20°C): approx. 2 K Ohms 

NOTE: Dip the sensor in ice water and measure the resistance. Then pour hot water on the sensor and check for change in resistance.

CAUTION: The sensor uses a thermistor which can be damaged if high current is applied to it during testing. Therefore, use a circuit tester that
puts out a measuring current of 1 mA or less. (At 20 K Ohm range)
 