MDX V6-3471cc 3.5L (2002)
7. Check for continuity between the following terminals of the climate control panel 16P connector and climate control unit connectors A (16P) and
B (26P).
Is there continuity?
YES - Go to step 8.
NO - Repair any open in the wire(s) between the climate control panel and climate control unit.
8. Check the continuity between the No.5, 6, and 14 terminals of the climate control panel 16P connector and body ground individually.
Is there continuity?
YES - Repair any short to body ground in the wire(s) between the climate control panel and the climate control unit.
NO - Check for loose wires or poor connections at climate control unit connector A (16P) and B (26P) and at the climate control panel 16P
connector. If the connections are good, substitute a known-good climate control panel, and recheck. If the symptom/indication is still present,
substitute a known-good climate control unit, and recheck.