Housing Assembly HVAC: All Technical Service Bulletins
A/C - Front Blower Motor Buzzing Noise

04-037

November 12, 2004

Applies To: 
2001-04 MDX - ALL

Buzzing From the Front Blower Motor

SYMPTOM

The front blower fan buzzes.

PROBABLE CAUSE

Debris accumulates around the wiper motor posts and under the cowl cover. Noise results from debris passing into the blower unit and blower motor.

CORRECTIVE ACTION

Remove the debris from the blower unit and the blower motor; replace the blower motor if necessary. Apply a seal to the wiper motor post clearance
holes.

PARTS INFORMATION

Seal D (two required):

P/N 74205-S0X-A00

WARRANTY CLAIM INFORMATION

In warranty:

The normal warranty applies.

Operation Number:

612002

Flat Rate Time:

0.7 hour

Failed Part:

74200-S3V-A01

Defect Code:

05401

Symptom Code:

04201

Skill Level:

Repair Technician

Out of warranty: 
Any repair performed after warranty expiration may be eligible for goodwill consideration by the District Parts and Service Manager or your Zone
Office. You must request consideration, and get a decision, before starting work.

REPAIR PROCEDURE

1.

Remove the right front door sill, the door opening trim, and the kick panel; pull the carpet aside.