acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Refueling Control Valve, Evaporative System|Locations|Page 5088 > < Refueling Control Valve, Evaporative System|Locations
Page 1
background image

Refueling Control Valve: Testing and Inspection

Fuel Tank Vapor Control Valve Test

Special Tools Required
Vacuum Pump/Gauge, 0 - 30 in.Hg A973X-041-XXXXX

Float Test

1. Make sure the fuel tank is less than half full.
2. Remove the fuel fill cap to relieve fuel tank pressure, then reinstall the cap.

3. Disconnect the fuel tank vapor recirculation tube (A), and connect a vacuum pump to the vapor recirculation tube.
4. Plug the pipe (B).
5. Apply vacuum to the fuel tank vapor recirculation tube (A).

-

If the vacuum holds, replace the fuel tank vapor control valve.

-

If the vacuum does not hold, the float is OK. Perform the valve test.

Valve Test

1. Make sure the fuel tank is less than half full.
2. Remove the fuel fill cap.

3. Disconnect the fuel tank vapor signal tube (A).

Refueling Control Valve, Evaporative System|Locations|Page 5088 > < Refueling Control Valve, Evaporative System|Locations