acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Fuel Delivery and Air Induction > < EGR Valve Position Sensor|Locations|Page 5182
Page 1
background image

Leak Detection Sensor: Testing and Inspection

EVAP Leak Monitor

NOTE:

-

When the battery negative cable is disconnected, all readiness codes are cleared.

-

If the engine is stopped while doing the procedure between step 6 and 16, do this procedure from step 1 again.

1. Make sure the gasoline level is 60 - 90 % of fuel tank capacity (not full).
2. Turn the ignition switch OFF.
3. Let the vehicle sit more than 8 hours.
4. Make sure the outside temperature is 20 - 95 °F (-7 - 35 °C).
5. Connect the scan tool to the Data Link Connector (DLC).
6. Start the engine and drive for about 15 minutes.
7. Keep the vehicle at a steady speed between 50 - 70 mph (80 - 114 km/h), without moving the accelerator pedal, for about 1 minute.
8. Stop the vehicle (do not stop engine).
9. Replace steps 7 and 8 two more times.

10. Check for the readiness code with the scan tool. If the readiness code does not set, go to step 11.
11. When ambient temperature is less than 32 °F (0 °C), hold the engine at 3,000 rpm with no load (in Park or neutral) until the radiator fan comes

on.

12. When ambient temperature is more than 86 °F (30 °C), remove the fuel fill cap, then install the fuel fill cap.
13. After step 12, drive for about 20 minutes on a freeway.
14. Keep the vehicle at a steady speed between 50 - 70 mph (80 - 114 km/h), without moving the accelerator pedal, for about 1 minute.
15. Stop the vehicle (do not stop the engine).
16. Repeat steps 14 and 15 two more times.
17. Check for the readiness code with the scan tool.

Fuel Delivery and Air Induction > < EGR Valve Position Sensor|Locations|Page 5182