acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Variable Induction Control Module > < Testing For a Short With a Short Circuit Locator (Short Finder)|Page 680
Page 4
background image

NO - Substitute a known-good PCM and recheck. If prescribed voltage is now available, replace the original PCM.

18. Remove the PGM-FI main relay.

19. Connect battery power to PGM-FI main relay 7P connector terminal No.2 and connect ground to PGM-FI main relay 7P connector terminal No.1.

Then check for continuity between PGM-FI main relay 7P connector terminals No.5 and No.4.

NOTE:  Use the terminal number shown. Ignore the terminal numbers molded into the relay.

Is there continuity?

YES - Go to step 19.

NO - Replace the PGM-FI main relay and reset.

20. Connect battery power to PGM-FI main relay 7P connector terminal No.5, and connect ground to PGM-FI main relay 7P connector terminal No.3.

Then check for continuity between PGM-FI main relay 7P connector terminals No.7 and No.6.

Is there continuity?

YES - Go to step 21.

NO - Replace the PGM-FI main relay and reset.

21. Connect battery power to PGM-FI main relay 7P connector terminal No.6, and connect ground to PGM-FI main relay 7P connector terminal No.1.

Then check for continuity between PGM-FI main relay 7P connector terminals No.5 and No.4.

Is there continuity?

YES - The PGM-FI main relay is OK.

NO - Replace the PGM-FI main relay and retest.

Variable Induction Control Module > < Testing For a Short With a Short Circuit Locator (Short Finder)|Page 680