acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Connecting Rod Bearing|Testing and Inspection|Page 1677 > < Testing For Voltage|Page 1672
Page 1
background image

Connecting Rod Bearing: Testing and Inspection

CLEARANCE

1. Remove the connecting rod cap and bearing half.
2. Clean the crankshaft rod journal and bearing half with a clean shop towel.
3. Place plastigage across the rod journal.
4. Reinstall the bearing half and cap, and torque the nuts.

NOTE:  Do not rotate the crankshaft during inspection.

5. Remove the rod cap and bearing half and measure the widest part of the plastigage. Make sure the clearance between the connecting rod and the

bearing is within the standard shown below.

Connecting Rod Bearing-to-Journal Oil Clearance:

Standard (New): 0.040 - 0.064 mm (0.0016 - 0.0025 inch)
Service Limit: 0.064 mm (0.0025 inch)
 

6. If the plastigage measures too wide or too narrow, remove the upper half of the bearing, install a new, complete bearing with the same color code,

and recheck the clearance.

CAUTION:  Do not file, shim, or scrape the bearing or the caps to adjust clearance.

7. If the plastigage shows the clearance is still incorrect, try the next larger or smaller bearing (the color listed above or below that one), and check

clearance again.

NOTE:  If the proper clearance cannot be obtained by using the appropriate larger or smaller bearings, replace the crankshaft and start over.

SELECTION 

CAUTION:  If the codes are indecipherable because of an accumulation of dirt and dust, do not scrub them with a wire brush or scraper. Clean them
only with solvent or detergent.

Connecting Rod Bearing|Testing and Inspection|Page 1677 > < Testing For Voltage|Page 1672