Modulator/Solenoid Unit: Description and Operation

MODULATOR COMPONENTS

Modulators and solenoid valves for each wheel are integrated in the modulator unit. 
-

The modulators for front and rear brakes are of independent construction. 

-

The solenoid valve features quick response (5 ms or less).

-

The inlet and outlet valves are integrated in the solenoid valve unit.

Fluid Flow During Base Braking

MODES OF OPERATION 

Base Braking Mode
In ordinary brake operations, the cut-off out valve in the modulator is open to transmit the hydraulic pressure from the master cylinder to the brake
calipers via the chamber A and the chamber B. The chamber C is connected to the reservoir through the outlet valve which is normally open. It is also
connected to the hydraulic pressure source (pump, accumulator, pressure switch, etc.) via the inlet valve which is normally closed. The chamber D

Component Locations|Page 5735 > < Component Locations|Page 5733