Connecting Rod Bearing: Testing and Inspection

MEASURING CONNECTING ROD CLEARANCE

1. Remove the connecting rod cap and bearing half.
2. Clean the crankshaft rod journal and bearing half with a clean shop towel.
3. Place plastigage across the rod journal.
4. Reinstall the bearing half and cap, and torque the nuts.

NOTE:  Do not rotate the crankshaft during inspection.

5. Remove the rod cap and bearing half and measure the widest part of the plastigage. Make sure the clearance between the connecting rod and the

bearing is within the standard shown below.
Connecting Rod Bearing-to-Journal Oil Clearance:

Standard (New): 0.040 - 0.064 mm (0.0016 - 0.0025 inch)
Service Limit: 0.064 mm (0.0025 inch)

6. If the plastigage measures too wide or too narrow, remove the upper half of the bearing, install a new, complete bearing with the same color code,

and recheck the clearance.

CAUTION: Do not file, shim, or scrape the bearing or the caps to adjust clearance.

7. If the plastigage shows the clearance is still incorrect, try the next larger or smaller bearing (the color listed above or below that one), and check

clearance again.

NOTE:  If the proper clearance cannot be obtained by using the appropriate larger or smaller bearings, replace the crankshaft and start over.