Air Door Actuator / Motor: Service and Repair
Recirculation Control Motor

1.  Remove the blower unit.

Recirculation Control Motor-Replacement

2.  Remove the three screws and the recirculation control motor cover from the blower unit.

Recirculation Control Motor-Replacement

3.  Remove the three screws and the recirculation control motor.
4.  Install the recirculation control motor in the reverse order of removal. Then apply battery voltage, and watch the door movement.

^  Make sure that the recirculation door moves smoothly without binding.
^  Make sure the motor doesn't pull the door too far.