Flowchart-Mode Control Motor (Part 2 Of 2)

Self-diagnosis indicator light G comes on: Indicates a problem in the mode control motor circuit. Use a digital multimeter (KS-AHM-32-003) to check it.

The mode control motor controls the outlet air direction and volume according to output from the climate control unit.

1.  Disconnect the mode control motor connector, turn the ignition switch ON (II), and move the blower switch to the middle setting.

Mode Control Motor-Test

2.  Connect battery power to the No. 1 terminal of the mode control motor, then connect ground to the No. 2 terminal. The mode control motor should

run, and stop at VENT.
If it doesn't, reverse the connections; the mode control motor should run, and stop at DEF.

NOTE:  If the mode control motor does not run, remove it, and check the mode control linkage and doors for smooth movement. If the mode
control linkage and doors move smoothly, replace the mode control motor.

3.  Plug the connector back into the motor. Operate the mode switch on the climate control unit to each mode. Verify that the mode control motor has