Condenser Fan: Component Tests and General Diagnostics
Condenser Fan Motor Test

Condenser Fan Motor Test

1.  Disconnect the 2P connector from the condenser fan motor.

NOTE: The illustration shows the right condenser.

2.  Test the motor by connecting battery power to the A terminal, and ground to the B terminal.
3.  If the motor fails to run or does not run smoothly, replace it.