acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Power Transistor HVAC > < High Pressure Safety Valve HVAC|Specifications
Page 1
background image

High Pressure Safety Valve HVAC: Service and Repair

Relief Valve Replacement

1.  Remove the relief valve and O-ring. 

Don't let any refrigerant oil run out.

NOTE:  Be sure to use the right O-rings for R-134a.

2.  Clean off the mating surface.
3.  Replace O-ring with new one at the relief valve, and apply refrigerant oil (ND-OIL 8) to it.

NOTE:
^  Do not return the oil to the container once dispensed and never mix with other refrigerant oils to avoid contamination.
^  Immediately after using the oil, replace the cap on the container and seal it to avoid moisture absorption.
^  Do not spill the refrigerant oil on the vehicle; it may damage the paint; if the refrigerant oil contacts the paint, wash it off immediately.

4.  Install and tighten the relief valve.
5.  Charge the system and check for leaks.

Power Transistor HVAC > < High Pressure Safety Valve HVAC|Specifications