acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Lamp Out Sensor > < Testing For Voltage|Page 8984
Page 1
background image

Key Reminder Switch: Testing and Inspection

NOTE:  Refer to Integrated Control Unit Circuit Diagram for a diagram of the key-in reminder circuit, and Key-in Reminder System input test for the
input test of the beeper circuit.

When the ignition key is not removed, the key-in reminder in the integrated control unit senses ground through the closed ignition key switch. When you
open the driver's door, the reminder circuit senses ground through the closed door switch. With ground at the "BLU/GRN" and "GRN/BLU2" terminals,
the beeper sounds.

Ignition Key Switch Test

1.  Remove the dashboard lower cover, and disconnect the floor wire harness connectors.
2.  Disconnect the 8P connector from the floor wire harness.

Ignition Key Switch Test

3.  There should be continuity between the No. 8 and No. 7 terminals when the ignition key is inserted. There should be no continuity with the

ignition key removed.

Lamp Out Sensor > < Testing For Voltage|Page 8984