acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Shift Control Solenoid Valve <--> [Shift Solenoid, A/T]|Component Testing|Page 4283 > < Shift Control Solenoid Valve <--> [Shift Solenoid, A/T]|Component Testing
Page 1
background image

Shift Control Solenoid Valve: Testing and Inspection
Shift Lock Solenoid Test

1.  Remove the center console panel and dashboard.
2.  Disconnect the 3P connector of the shift lock solenoid from the floor wire harness.

NOTE:  This solenoid has a diode in it. To get an accurate reading, either test it with a volt-ohmmeter that compensates for diodes, or make sure
you connect your test leads to match the polarity shown.

Shift Lock Solenoid Test/Replacement

3.  Connect battery power to the A terminal and ground to the B terminal momentarily, and check to see if the solenoid works.

If it does not work, replace it.

If it works, go to step 3.

Shift Lock Solenoid Test/Replacement

4.  When the shift lock solenoid is ON, check that there is a clearance of 2.5 ± 0.5 mm (0.098 ± 0.020 in) between the top corner of the shift lock

lever and the side of the lock pin.

If clearance is correct, go to the next step.

If clearance is incorrect, loosen the self-locking nuts, and adjust the solenoid as needed.

Shift Lock Solenoid Test/Replacement

5.  When the shift lock solenoid is OFF, make sure that the lock pin is blocked by the top of the shift lock lever.

If it is not blocked, adjust the position of the shift lock solenoid as needed to block it.