8. Use the arrow or number keys to select FLOODED, then press Enter.

NOTE:

All Acura original equipment and replacement batteries are flooded types. If you select another battery type, your claim will not be covered by
Acura's warranty.

9. Use the arrow or number keys to select the battery CCA value, then press Enter. You can find the CCA on the battery label on the top of the battery.

If the battery hold-down plate is covering the label, loosen the plate and shift it out of the way to read the CCA.

NOTE:

Enter the correct cold cranking amps. If you enter the wrong number, the GR8 result may be wrong, and the warranty claim may be rejected.

10. The screen changes to a progress bar while the GR8 tests the battery.

11. If the battery voltage is below 60% of its state of charge (SOC), or the condition of the battery is unknown, the GR8 automatically starts charging

the battery and diagnosing it.

NOTE:

^

The GR8 often states that charging and testing time is about 3 hours. Most actual charging and diagnostic times range between 15-25
minutes.