4. Remove the sub relay box A and the water drain duct. Disconnect the connectors from the blower, power transistor and recirculation control
motor.
5. Remove the blower mounting bolts, then remove the blower.
6. Install the blower in the reverse order of removal, then make sure it runs and doesn't leak any air.