Connecting Rod: Testing and Inspection
Connecting Rod and Crankshaft End Play Inspection

Connecting Rod and Crankshaft End Play Inspection 

1. Remove the oil pump.
2. Remove the baffle plate.
3. Measure the connecting rod end play with a feeler gauge between the connecting rod and crankshaft.

4. If the connecting rod end play is beyond service limit, install a new connecting rod, and recheck. If it is still beyond service limit; replace the 

crankshaft.

5. Push the crankshaft firmly away from the dial indicator, and zero the dial against the end of the crankshaft. Then pull the crankshaft firmly back

toward the indicator; the dial reading should not exceed the service limit.

6. If the end play is beyond service limit, replace the thrust washers and recheck, if it is still beyond service limit, replace the crankshaft.