17. Replace the gasket with a new one when installing the solenoid cover.

18. Disconnect the connector from the shift solenoid valve(s) that did not click.

19. Measure the resistance of shift solenoid valve between the connector terminal and body ground.

-

If the resistance is out of standard, go to step 22 and replace the shift solenoid valve.

-

If the resistance is within the standard, go to step 20 and check the solenoid valve for a clicking sound.

20. Connect a jumper wire from the negative battery terminal to the body ground, and connect another jumper wire from the positive battery terminal