acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Air Door Actuator / Motor Relay > < Rear Vent Control Motor Replacement|Page 8480
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Recirculation Control Motor Replacement

Recirculation Control Motor Replacement

1. Remove the glove box housing.

2. Disconnect the 5P connector (A) from the recirculation control motor (B). Remove the self tapping screws and the recirculation control motor

from the blower unit.

3. Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make

sure the motor runs smoothly.

Air Door Actuator / Motor Relay > < Rear Vent Control Motor Replacement|Page 8480