acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Malfunction Indicator Lamp > < PGM-FI System|Page 3966
Page 2
background image

Check for continuity between the terminals.

-

There should be continuity between the No.  1 and No.  2 terminals when power is connected to the No. 4 terminal and ground the No. 3 terminal.

-

There should be no continuity between the No. 1 and No. 2 terminals when power is disconnected.

Malfunction Indicator Lamp > < PGM-FI System|Page 3966