6. Remove the snap ring, then remove the outer side plate, cam ring, rotor, vanes, side plate, and O-rings.
7. Remove the snap ring, then remove the pump driveshaft by tapping the shaft end with the plastic hammer.
8. Remove the seal from the pump housing.

Inspection

9. Check the flow control valve for wear, burrs, and other damage to the edges of the grooves in the valve.

10. Inspect the bore of the flow control valve on the pump housing for scratches and wear.
11. Slip the flow control valve back in the pump housing, and check that it moves in and out smoothly. If OK, go to step 12; if not, replace the pump

as an assembly. The flow control valve (A) is not available separately.

12. Attach a hose (A) to the end of the flow control valve (B) as shown. Then submerge the flow control valve in a container of power steering fluid or

solvent (C), and blow in the hose.
-

If air bubbles leak through the valve at less than 98 kPa (1.0 kgf/cm2, 14.2 psi), replace the pump as an assembly. The flow control valve is
not available separately.

-

If the flow control valve is OK, set it aside for reassembly later.

Reassembly

13. Install the oil seal (A) (with its grooved side facing in) into the pump housing by hand first. Press the oil seal with the appropriate size socket

wrench (B) as shown.