Check for continuity between the terminals.

-

There should be continuity between the No.  1 and No.  2 terminals when power is connected to the No. 4 terminal and ground the No. 3 terminal.

-

There should be no continuity between the No. 1 and No. 2 terminals when power is disconnected.