acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Exhaust Gas Recirculation > < Leak Detection Solenoid, Evaporative System|Diagrams
Page 1
background image

Leak Detection Solenoid: Service and Repair

EVAP Canister Vent Shut Valve Replacement

1. Remove the trunk front trim panel.  See: Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Trunk / Liftgate Interior Trim Panel/Service

and Repair/Interior Trim Removal/Installation - Trunk Area

2. Remove the access panel (A) from the floor.

3. Disconnect the EVAP canister vent shut valve 2P connector (A), FTP sensor 3P connector (B), and the hose (C).

4. Pry the lock tabs (D) outward, and remove the EVAP canister vent shut valve (E).

NOTE: Be careful not to damage the lock tabs.

5. Install the parts in the reverse order of removal with a new O-ring (F).

NOTE: Do not coat the new O-ring with oil or other lubricants.