RL V6-3.7L (2009)
Reconnection to existing retainer
Connection to new fuel line
5. When you reconnect the connector with the old retainer, make sure the connection is secure and the tabs (A) are firmly locked into place; check
visually and also by pulling the connector (B). When you replace the fuel line with a new one, make sure you remove the ring pull (C) upwards
after you confirm the connection is secure.
NOTE: Before you remove the ring pull, make sure the fuel line connection is secure. If the connection is not secure, the ring pull could break
when you try to remove it.
6. Do the battery terminal reconnection procedure, See: Starting and Charging/Battery/Service and Repair/Procedures and turn the ignition switch to
ON (II) (but do not operate the starter motor). The fuel pump will run for about 2 seconds, and fuel pressure will rise. Repeat this two or three
times, and check that there is no leakage in the fuel supply system.
Reconnection to existing retainer