acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Actuator Test|Page 12107 > < Actuator Test
Page 2
background image

5. With voltage and vacuum still applied, try to pull the actuator rod out by hand. You should not be able to pull it out. If you can, it is defective.
6. Disconnect ground from the No.3 terminal. The actuator rod should return. If it does not return, and the vent hose and filter are not plugged, the

solenoid valve assembly is defective.

7. Repeat steps 2 through 5, and disconnect ground from the No.1 terminal. The actuator rod should return. If it does not return, and the vent hose

and filter are not plugged, the solenoid valve assembly is defective.

8. If you replace the solenoid valve assembly, be sure to use new O-rings on each solenoid.
9. Disconnect power and ground from the 4P connector. Disconnect the vent hose from the actuator. Connect a vacuum pump to the actuator vent

hose Pont, and apply vacuum. The actuator rod should pull in completely. If not, the vacuum valve is stuck open. Replace the actuator.

Actuator Test|Page 12107 > < Actuator Test