Thermostat: Testing and Inspection

Testing

Replace the thermostat if it is open at room temperature.
To test a closed thermostat:

1. Suspend the thermostat in a container of water.
2. Heat the water, and check the temperature with a thermometer. Check the temperature at which the thermostat first opens, and at which it is fully

open.

CAUTION:  Do not let the thermometer touch the bottom of the hot container.

3. Measure lift height of the thermostat when it is fully open.

STANDARD THERMOSTAT
Lift height: above 10.0 mm (0.39 inch)
Starts opening: 169° - 176°F 176° - 80°C)
Fully open: 194°F (90°C)