acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Air Door Cable, HVAC > < Air Mix Control Motor Replacement|Page 9613
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Recirculation Control Motor

1. Remove the glove box.
2. Remove the glove box back cover.

3. Disconnect the wire harness clip and the connector from the recirculation control motor, then remove the self-tapping screws and the recirculation

control motor.

4. Install in the reverse order of removal. After installation, make sure the recirculation control motor runs smoothly.

Air Door Cable, HVAC > < Air Mix Control Motor Replacement|Page 9613