acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Blower Unit Removal and Installation|Page 9644 > < Symptom Related Diagnostic Procedures|Page 9641
Page 1
background image

Blower Motor: Service and Repair
Blower Unit Removal and Installation

SRS components are located in this area. Review the SRS component locations, precautions, and procedures before performing repairs or service.

1. Recover the refrigerant with a recovery/recycling/charging station.

2. Remove the bolt and the clamp from the evaporator. Remove the bolt, then disconnect the capillary tube from the suction line. Remove the bolts,

then disconnect the suction and receiver lines from the evaporator. Remove the mounting nut from the evaporator.

NOTE:
-

Be careful not to damage or bend the capillary tube.

-

Plug or cap the lines immediately after disconnecting them to avoid moisture and dust contamination.

3. Turn the ignition switch ON (II), and set the recirculation control switch on RECIRCULATE.
4. Remove the glove box.

5. Remove the trunk opener main switch connector, the self-tapping screws and the glove box back cover.

Blower Unit Removal and Installation|Page 9644 > < Symptom Related Diagnostic Procedures|Page 9641