Power Window Relay: Testing and Inspection
Normally-Open Type B

NOTE:  See turn signal/hazard relay input test.

Normally-open type B:

Check for continuity between the terminals.

-

There should be continuity between the No.1 and No.3 terminals when power and ground are connected to the No.2 and No.4 terminals.

-

There should be no continuity between the No.1 and No.3 terminals when power is disconnected.

Power window Relay