acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Electrical Specifications|Page 6661 > < Electrical Specifications|Page 6659
Page 2
background image

4. Measure the resistance between the No. 3 and No. 4 terminals of the shift control solenoid valve/linear solenoid harness connector.

STANDARD: 4.0 - 6.0 Ohms (at 70°F, 20°C) 

-

If the resistance is within specification, replace the transmission sub-harness.

-

If the resistance is out of specification, replace the linear solenoid.

5. If the resistance is within the standard, connect the No. 4 terminal of the shift control solenoid valve/linear solenoid harness connector to the

battery positive terminal, and connect the No. 3 terminal to the battery negative terminal. A clicking sound should be heard. If no clicking sound is
heard, replace the linear solenoid.

NOTE: 
If the linear solenoid replacement is required, refer to:
-

Lower Valve Body
Removal/Installation
Disassembly/Reassembly

-

Throttle Valve Body/Linear Solenoid
Replacement

Electrical Specifications|Page 6661 > < Electrical Specifications|Page 6659