Power Window Relay: Testing and Inspection
Driver's Power Window Motor Relay B

Five-Terminal Type B:

Check for continuity between the terminals.

-

There should be continuity between the No.1 and No.2 terminals when power and ground are connected to the No.3 and No.5 terminals.

-

There should be continuity between the No.2 and No.4 terminals when power is disconnected.