acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Evaporator Core > < Control Module HVAC|Testing and Inspection|Page 6263
Page 1
background image

Coolant Temperature Sensor / Switch HVAC: Testing and Inspection

ECT Sensor Circuit Troubleshooting

1. Check the malfunction indicator lamp (MIL). Does the malfunction indicator lamp come on?

YES - Refer to the powertrain DTCs.

NO - Go to step 2.

2. Turn the ignition switch OFF.
3. Disconnect the ECT sensor 2P connector.
4. Disconnect the climate control unit 30P connector.
5. Turn the ignition switch ON (II).

6. Measure the voltage between the No. 18 terminal of the climate control unit 30P connector and body ground.

Is there about 5 V?

YES - Check for loose wires or poor connections at the climate control unit 30P connector and at the ECT sensor 2P connector. If the connections
are good, substitute a known-good climate control unit, and recheck. If the symptom/indication goes away, replace the original climate control unit

NO - Repair open in the wire between the climate control unit and the ECT sensor.

Evaporator Core > < Control Module HVAC|Testing and Inspection|Page 6263