acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Relays and Modules - HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 9514
Page 2
background image

YES - Check for loose wires or poor connections at the climate control unit 30P connector and at the A/C pressure switch 2P connector. If the
connections are good, substitute a known-good climate control unit, and recheck. If the symptom/indication goes away, replace the original climate
control unit.

NO - Repair open in the wire between the climate control unit and the A/C pressure switch.

10. Make sure the A/C switch is OFF.

11. Measure the voltage between the No.9 terminal of under-dash fuse/relay box connector F (12P) and body ground with the under-dash fuse/relay

box connectors connected.

Is there battery voltage?

YES - Repair open in the wire between the under-dash fuse/relay box and the A/C pressure switch.

NO - Refer to the multiplex control system.

12. Check for proper A/C system pressure.

Is the pressure within specifications? 

YES - Replace the A/C pressure switch.

NO - Repair the A/C pressure problem.

Relays and Modules - HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 9514