Blower Motor: Service and Repair
Blower Unit Removal and Installation

1.  Remove the evaporator.

2.  Remove the mounting nut from the blower unit.

NOTE: When removing the mounting nut, take care not to damage or bend the fuel pipes, brake pipes, etc.

3.  Disconnect the connector from the recirculation control motor, and remove the self-tapping screw from the pipe clamp.

4.  Remove the mounting bolt, then remove the blower unit by moving it back and toward the right.