acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Lamp Out Indicator > < Testing For a Short to Ground With a Short Circuit Locator|Page 8732
Page 1
background image

Key Reminder Switch: Testing and Inspection

SRS components are located in this area. Review the SRS component locations, precautions, and procedures in the SRS section before performing
repairs or service.

NOTE: Refer to Integrated Control Unit for the diagram of the key- in beeper circuit, and Integrated Control Unit Input test for the input test of the
beeper circuit.

Ignition Key Switch Test

When the ignition key is not removed, the key-in beeper in the integrated control unit senses ground through the closed ignition key switch. When you
open the driver's door, the beeper circuit senses ground through the closed door switch. With ground at the "BLU/WHT2,, and "A13" terminals, the
beeper sounds.

1.  Remove the dashboard lower cover and knee bolster.
2.  Disconnect the 8P connector from the main wire harness.
3.  Check continuity between terminals No. 4 and No. 7.

^  There should be continuity with the key in the ignition switch.
^  There should be no continuity with the key removed.

Lamp Out Indicator > < Testing For a Short to Ground With a Short Circuit Locator|Page 8732