TL L5-2451cc 2.5L SOHC MFI (1997)
Solar Sensor: Testing and Inspection
Sunlight Sensor Test
Turn the ignition switch ON (II). Measure the voltage between the terminals with the 1+1 probe on the No. 1 terminal and the (-) probe on the No. 2
terminal with the 2P connector connected. Voltage should be;
^ 3.7 ± 0.2 V or more with the sensor out of direct sunlight.
^ 3.6 ± 0.2 V or less with the sensor in direct sunlight.
NOTE: The voltage will not change under the light of a flashlight or a fluorescent lamp.