acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Timing Belt|Testing and Inspection|Page 2357 > < Timing Belt|Testing and Inspection|Page 2355
Page 6
background image

NOTE:  The compression pressure should not exceed 9,800 N (1,000 kgf, 2,200 lbs.).

Belt Tensioner Installation and Torque

8. Install the auto-tensioner.

NOTE:  Make sure the pin stays in place.

9. Screw the battery clamp bolt in as shown to hold the timing belt adjuster. Tighten it by hand, do not use a wrench.

10. Apply liquid thread lock (P/N 08713-0001) to the idler pulley bolt, then loosely install the idler pulley.

11. Install the timing belt in a Counterclockwise sequence starting with the drive pulley.

Timing Belt|Testing and Inspection|Page 2357 > < Timing Belt|Testing and Inspection|Page 2355