TL V6-3.2L (2004)
3. When the desired correction value appears on the display, release the button, and the recalibrated outside air temperature will be displayed. Each
time a desired correction valve is entered, it replaces the previous valve.
Example:
Incorrect value = 68 °F (20 °C)
Desired correction valve = +2 °F ( +1 °C)
Correct valve = 70 °F (21 °C)
Desired correction valve = -2 °F (-1 °C)
Correct valve = 66 °F (19 °C)
NOTE: To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the
sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the
true temperature.