TL V6-3.2L (2004)
Canister Vent Valve: Service and Repair
EVAP Canister Vent Shut Valve Replacement
1. Remove the EVAP canister.
2. Open the stopper (A) and then remove the EVAP canister vent shut valve (B).
NOTE: Be careful not to damage the stoppers.
3. Install the valve in the reverse order of removal with a new O-ring (C).
NOTE: Do not coat the O-ring with oil.